Wang QS, Ping P, Sun JH, Chen CH (2011a) Journal of Power Sources 196(14), 5960-5965.
文章来源:WOS    作者:SKLFS    发布时间:2011-08-16
Wang QS, Ping P, Sun JH, Chen CH (2011a) Cresyl diphenyl phosphate effect on the thermal stabilities and electrochemical performances of electrodes in lithium ion battery. Journal of Power Sources 196(14), 5960-5965. [In English]

Web link: http://dx.doi.org/10.1016/j.jpowsour.2010.12.051

Keywords:

Lithium ion battery; Thermal behavior; C80 micro calorimeter; Cresyl; diphenyl phosphate; behavior; electrolytes; cells

Abstract: To improve the safety of lithium ion battery, cresyl diphenyl phosphate (COP) is used as a flame-retardant additive in a LiPF6 based electrolyte. The electrochemical performances of LiCoO(2)/CDP-electrolyte/Li and Li/CDP-electrolyte/C half cells are evaluated. The thermal behaviors of Li(0.5)CoO(2) and Li(0.5)CoO(2)-CDP-electrolyte, and Li(x)C(6) and Li(x)C(6)-CDP-electrolyte are examined using a C80 micro-calorimeter. For the LiCoO(2)/CDP-electrolyte/Li cells, the onset temperature of single Li(0.5)CoO(2) is put off and the heat generation is decreased greatly except the one corresponding to 5% CDP-containing electrolyte. When Li(0.5)CoO(2) coexists with CDP-electrolyte, the thermal stability is enhanced. COP improves the thermal stability of lithiated graphite anode effectively and the addition of 5% CDP inhibits the decomposition of solid electrolyte interphase (SEI) films significantly. The electrochemical tests on LiCoO(2)/CDP-electrolyte/Li and Li/CDP-electrolyte/C cells show that when less than 15% COP is added to the electrolyte, the electrochemical performances are not worsen too much. Therefore, the addition of 5-15% COP to the electrolyte almost does not worsen the electrochemical performance of LiCoO(2) cathode and graphite anode, and improves theirs thermal stability significantly; thus, it is a possible choice for electrolyte additive. (C) 2011 Published by Elsevier B.V.

 
 
相关链接
Wang QS, Ping P, Sun JH, Chen CH (2011a) Journal of Power Sources 196(14), 5960-5965.
联系我们
安徽省合肥市金寨路96号
图书馆VIP
火灾科学国家重点实验室
邮政编码:230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.tsg211.com
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
火灾科学国家重点实验室 版权所有 皖ICP备:002106505 号