首页  科学研究  学术论文  2014年
 
W. G. An, Z. Wang, H. H. Xiao, J. H. Sun and K. M. Liew (2014) Energy Conversion And Management 88 516-524.
文章来源:SKLFS    作者:SKLFS    发布时间:2015-03-30

W. G. An, Z. Wang, H. H. Xiao, J. H. Sun and K. M. Liew (2014) Thermal and fire risk analysis of typical insulation material in a high elevation area: Influence of sidewalls, dimension and pressure. Journal/Energy Conversion And Management 88 516-524. [In English]
Web link: http://dx.doi.org/10.1016/j.enconman.2014.08.026
Keywords: Energy saving; Extruded polystyrene (XPS); Risk evaluation; Combustion; characteristics; Downward flame spread; Heat transfer; HEAT-TRANSFER MECHANISMS; FLAME SPREAD; BUILDING WALLS; ORIENTATIONS; CLIMATE; OXYGEN; WOOD; LOAD

Abstract: Small-scaled experiments and modeling are performed to investigate the downward flame spread over extruded polystyrene (XPS) slabs at different widths with and without sidewalls in a city (Lhasa, China) at high elevation. This study provides an understanding of the thermal characteristics and fire risk of XPS under the influence of various factors. It is found that the flame pulsation is more significant for wider samples. The average flame height (H) rises as the width increases. Compared to the results obtained without sidewalls, the flame pulsation is less considerable and H is higher for samples with sidewalls. When sidewalls are present, the average maximum flame temperature (T-max) increases with the rise of sample width, and it is lower than that without sidewalls. T-max in the combustion zone besides the sidewalls is larger than that in the middle zone, while the reverse is true for samples without sidewall. The solid-phase temperature curve is comprised of three stages. The temperature growth rate is low during the melting stage. The duration of the melting stage without sidewalls is longer than that with sidewalls. This duration at a low elevation is shorter than that at the high elevation. The shorter duration of the melting stage corresponds to the higher temperature at which the melting stage occurs. A three dimensional downward flame spread model taking into account the effects of sample width, thickness, ambient pressure and sidewall is established. The predicted trends of V-f using the model agree well with the experimental results. The model could also predict XPS fire hazard. The thermal and risk analysis of XPS provides a guidance to fire safety design of energy saving system of buildings. (C) 2014 Elsevier Ltd. All rights reserved.

 
 
相关链接
W. G. An, Z. Wang, H. H. Xiao, J. H. Sun and K. M. Liew (2014) Energy Conversion And Management 88 516-524.
联系我们
安徽省合肥市金寨路96号
图书馆VIP
火灾科学国家重点实验室
邮政编码:230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.tsg211.com
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
火灾科学国家重点实验室 版权所有 皖ICP备:002106505 号