首页  科学研究  学术论文  2015年
 
W. G. An, L. Jiang, J. H. Sun and K. M. Liew (2015) Journal Of Thermal Analysis And Calorimetry 119 229-238.
文章来源:SKLFS    作者:SKLFS    发布时间:2016-03-02

W. G. An, L. Jiang, J. H. Sun and K. M. Liew (2015) Correlation analysis of sample thickness, heat flux, and cone calorimetry test data of polystyrene foam. Journal/Journal Of Thermal Analysis And Calorimetry 119 229-238. [In English]
Web link: http://dx.doi.org/10.1007/s10973-014-4165-9
Keywords: Polystyrene; Cone calorimeter; Sample thickness effect; Ignition time; Heat release rate; Correlation analysis; FIRE; BEHAVIOR; WOOD; RELEASE
Abstract: This paper deals with thermal and fire performance evaluation of expanded polystyrene (EPS) and extruded polystyrene (XPS) in a cone calorimeter with a piloted ignition. The correlation analysis of sample thickness, heat flux (q) over dot '', and experimental results is performed. It is found that the heat flux follows a linear function of the vertical distance from the standard horizontal level to the sample. An optimization ignition model is established considering the effects of sample thickness (or radiant distance). The modified ignition time ((t) over bar (ig)) decreases with the increase of the sample thickness. Both t(ig) (ignition time) and (t) over bar (ig) drop as external heat flux rises. EPS's t(ig) is more sensitive to the variation of external heat flux. Thermal thickness (delta(P)) decreases with the intensifying of heat flux, and delta(P) is in linear correlation with rho/(q) over dot ''. When sample is quite thin or the irradiance level is low (2 cm-thick PS under 35 kW m(-2) and 3 cm-thick EPS under 25 kW m(-2)), single peak heat release rate (HRR) is present. Under other situations, there are at least two peak values. For EPS, the first peak value is higher than the last, while the reverse is true for XPS (exclusive of 5 cm-thick XPS at 35 kW m(-2)). Both peak and mean HRR rise linearly with the increase of external heat flux. t(ig), (t) over bar (ig), critical heat flux and delta(P) of XPS are smaller than those of EPS, while the reverse is true for mean HRR. The ignition and heat release risk of PS drop with the decrease of external heat flux, and these hazards of XPS are higher than those of EPS.


 

 
 
相关链接
W. G. An, L. Jiang, J. H. Sun and K. M. Liew (2015) Journal Of Thermal Analysis And Calorimetry 119 229-238.
联系我们
安徽省合肥市金寨路96号
图书馆VIP
火灾科学国家重点实验室
邮政编码:230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.tsg211.com
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
火灾科学国家重点实验室 版权所有 皖ICP备:002106505 号